Visit WADEPROJECTS.COM
for Wade's current SSES and I/I programs. |
|
Like many other communities, Tulsa,
Oklahoma's first Sanitary Sewer Evaluation Study satisfied an
EPA consent order, but didn't bring about a noticeable decrease
in overflows. During a recent study though, Wade & Associates
helped them locate all the problems within the system before starting
rehabilitation instead of spot-fixing isolated problems. |
Using
proven methods, our crews precisely locate
and quantify the majority of I/I in your system. |
Flow Monitoring Programs and Surveys |
| Our team of experienced
engineers and field technicians can conduct a wide variety of flow
monitoring programs to target areas within the collection system
that need further investigation and rehabilitation. Our field teams
have extensive experience with flow meters, including installation,
calibration, and data analysis. We can also assist you with meter
site selection and rainfall monitoring.
|
 |
 |
|
For example, in Clinton,
MO, a study was conducted
to measure and quantify the amounts of normal base (dry-weather)
flow, infiltration, and inflow (I/I) that enter into each of the
City's eight (8) drainage basins by installing, calibrating and
servicing flow meters and then analyzing the data that was collected. |
Manhole Inspections & Visual Pipe Inspections
To ensure the most cost-effective rehab of your collection system,
we emphasize those field activities that identify inflow, as opposed
to infiltration. Since we've found that 50% or more of inflow enters
into municipal sewer systems through manhole structures, we typically
begin here. We target manholes for follow-up rehabilitation and
help you develop utility maps of your system, a rehab schedule and
an engineer's estimate for construction, if necessary.
Our trained inspection teams follow the latest OSHA regulations
on confined space entry. During these inspections, we lamp all incoming
and outgoing lines to spot early signs of pipe deterioration, root
intrusion, deposition, and other defects associated with excessive
I/I or structural deterioration.
|
|
 |
|
| When manhole defects ranging from
leaking, vented manhole covers or failed frame seals to manholes
with severe structural deficiencies were found to be significant
contributors of I/I in Sioux
Falls, South Dakota, Stockwell Engineers retained Wade &
Associates to provide direction and support for a manhole rehabilitation
project involving 1,500 manholes. The firm provided training and
quality control for the inspection program as well as the hydraulic
modeling that followed. |
Smoke Testing |
| We use state-of-the-art
equipment to conduct smoke testing (or rain simulation tests) of
your collection system. This allows us to locate most inflow sources
that cause sewer systems to overflow and bypass during significant
storm events. We will prepare an effective public relations program
that will minimize public concern where smoke enters into private
residences through plumbing defects.
|
 |
|
All defects are carefully documented for follow-up rehabilitation.
The Lake Cities Metropolitan Utility Authority (Lake
Dallas, TX) selected Wade & Associates to conduct smoke
testing of 112,000 feet of sanitary sewers in order to locate, document
and characterize defects within the sewer system. At the conclusion
of the tests, Wade submitted full documentation of the work performed
including hard copies of all field forms, photographs, and tabular
summaries. |
Building Inspections
If evidence shows the potential for significant I/I from private
property, our crews can conduct comprehensive building inspections
to pinpoint unwanted I/I connections to the municipal sewer system-all
at minimal disturbance to building residence. Studies show that
more than 50% of I/I can enter into the sewer system from the private
sector. Combined with smoke testing and follow-up dyed-water testing,
building inspections can effectively locate these sources. |
| |
The Fort
Scott, KS collection system had been experiencing excessive
wet-weather induced wastewater flows. When Wade & Associates
conducted building inspections, they found 3,500 to 4,000 building
properties that had service laterals connected to the collection
system, and the majority of homes in the system had basements. |
CCTV Inspections |
|  |
Where smoke testing and visual pipe
inspections do not indicate the extent of a particular I/I source,
CCTV inspections can provide the information cities need to quantify
the connections and determine the best repair method. Often, our
field team will pre-clean line segments targeted for TV inspection.
Observations are videotaped and documented in a computer database
for further analysis.
In Fort Worth,
TX, the small diameter
cleaning project of 320,000 lf of 6- to 15-inch pipe included
CCTV inspection of 60,000 lf, which, after analysis, resulted in
specific rehabilitation recommendations for 40,000 lf of sewer pipeline. |
Dyed-Water Testing
During some TV inspections, crews will concurrently dye test selected
locations to aid in the detection of a specific I/I source. Dyed-water
testing is also used to confirm I/I connections from private property. |
Visit WADEPROJECTS.COM
for Wade's current SSES and I/I programs.
Other Wade SSES Projects: |
| Bartlesville,
Oklahoma
Carrboro, North Carolina
Topeka, Kansas |
Fort Worth, Texas
Springfield, Missouri |
Copyright
©2006 Wade & Associates
|